Pressure transmitter for the gauging of relative pressure

relative pressure sensor with lcd
7 incentives wherefore also you should purchase relative pressure sensors by Senti-Solutions.com:
- Item-by-item measurement ranges according to your demands
- You receive a calibrating testification to any bought relative pressure sensing element on inquiry; completely free of cost!
- No Asia import, our relative pressure detectors are produced here in Federal Republic of Germany!
- Save yourself storehouse rates by covering bigger product bands with fewer pressure transmitters. How this goes? Further read!
- Switch-selectable regular measurement ranges, i.e. You purchase 1 relative pressure sensor for 3 different measurement ranges (at competing products you must buy 3 parts for)
- Switch-selectable output signals, i.e. You acquire 1 relative pressure sensing element and can fix the output signal at the pressure transducer, (at rival products you must purchase a pressure sensor for every output signal)
- You have read totally correctly! To reach the performance range of one of our relative pressure transducers, you should acquire at least 9 rival products! Save yourself the cash!
We have not persuaded you with these 7 arguments yet? Be of use for our contact form and illustrate us your problem! Solution approved!
How do our relative pressure transmitter operate? Read this in our summarization!
The relative pressure-measuring sensor can be distributed for relative pressure in a high-grade steel execution. The relative pressure can be measured in liquids and aggressive media with that. At this construction the measuring element consists of a pressure sensor established in thin film technology on a exorbitant-grade iron steel membrane. It is in consequence warranted that all medium touching parts consist of high-grade iron steel completely. A wheatstone resistance bridge is used for the measuring at this pressure detector. By use of a semiconductor chip the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Previous to shipment this pressure transmitter is calibrated to be able to warrantee a high correctness and reliability.
This pressure-measuring transmitter can be distributed with the output signals 0 …. 10 V, 4 …. 20 mA or 0 …. 20 mA.
The use of these pressure sensors for relative pressure is carried out in pneumatics, process measuring technique and in the building technology. The pressure transmitter could also be delivered with an EEx-approval.
Each relative pressure pressure transmitter can be delivered on inquiry with calibrating testification also with DKD-calibrating testification.
Do you have even further questions? Use our contact form!

relative pressure sensor in high-grade steel
You find the technical data of the relative pressure sensor here:
| characteristic | description |
| output | 0 … 10 V // 4 … 20 mA // gSPI other variants: inverse output // output with root extraction |
| Pressure sensor | Pressure sensing element in thin film technology with a wheatstone resistance bridge |
| power Supply | 14 … 30 V DC // 15 … 27 V AC |
| non linear error | +/- 0,5 % FS |
| total error | +/- 0,7 % FS |
| electrical coupling | connector DIN EN175301-803 BF C others in approval to customer requirements |
| process connection | G 1/4″ others in grant to client demands |
| process temperature | - 20 … + 85 °C other ranges according to customer requirements |
| enviromental temperature | - 20 … + 85 °C other ranges according to customer requirements |
| case | metall material others according to customer requirements |
| membrane | extreme-grade steel without oil intermediate layer |
| safety class | IP 65 |
| overload range | 1,5-fold |
| max. pressure load | 2-fold |
| also with EEx-approval |
You find a survey of the measurement ranges of the relative pressure sensor into exorbitant-grade iron steel here:
| measurement range |
| 60 kPa (0,6 bar) |
| 100 kPa (1 bar) |
| 160 kPa (1,6 bar) |
| 250 kPa (2,5 bar) |
| 400 kPa (4 bar) |
| 600 kPa (6 bar) |
| 1000 kPa (1 MPa resp. 10 bar) |
| 1600 kPa (1,6 MPa resp. 16 bar) |
| 2500 kPa (2,5 MPa resp. 25 bar) |
| 4000 kPa (4 MPa resp. 40 bar) |
| 6000 kPa (6 MPa resp. 60 bar) |
| 10000 kPa (10 MPa resp. 100 bar) |
| 16000 kPa (16 MPa resp. 160 bar) |
| 25000 kPa (25 MPa resp. 250 bar) |
| 40000 kPa (40 MPa resp. 400 bar) |
| other alternatives: other ranges according to customer requirements |
Convinced You? Then contact us now!
Advices
You may link to this page!
The pressure transmitter is maintenance-free.
This site was arranged with attention. It, however, was not possible to take into answer for all imaginable application circumstances. If you should consider to miss hints for your special formulation, use the contact form for your doubts.
Notes for safety arguments
Observe the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) relatively for assembly, putting into operation and operation of these pressure sensors.
Mistakes and changes in the sense of technical improvementsreserved.
Print This Post
No related posts.