Pressure switch for the metering of pressure

pressure switch with lcd
7 causes wherefore also you should buy a pressure switch by Senti-Solutions.com:
- Individual measurement ranges in approval to your demands
- You receive a calibrating certificate to any bought pressure switch on request; entirely gratis!
- No Asia importation, our pressure switch are assembled here in Germany!
- Save yourself storehouse expenses by including larger product bands with less pressure switches. How this goes? Further read!
- Switch-selectable approved measurement ranges, i.e. You buy 1 pressure switch for 3 different measurement ranges (at rival products you must acquire 3 parts for)
- Switch-selectable output signals, i.e. You acquire 1 absolute pressure switch and can fix the output signal at the pressure switch, (at rival products you must acquire a pressure sensor for every output signal)
- You have read entirely right! To achieve the performance range of one of our pressure switches, you should acquire at least 9 rival goods! Save yourself the cash!
We have not convinced you with these 7 incentives yet? Be of use for our contact form and describe us your problem! Solution guaranteed!
How do our pressure switch function? Study this in our summarization!
The pressure in non-aggressive gasses and atmospheres can be grasp with the pressure switch for the metering of pressure. The used metering item is a pressure detector produced into Si technology. The pressure sensor use a wheatstone resistance bridge for the capturing of the pressure alteration which was diffused into the silicon crystal. The measurement signal gets temperature and pressure compensated by means of IC. Each pressure switch will be calibrated during the assembling method. Through this a high reliability and correctness of the pressure sensor is guaranteed.
Dissimilar signals are ready for use as an output signal depending on application example. Besides the norm signals of 0 …. 10 V or 4 …. 20 mA the pressure switch can also be delivered with a gSPI interface. It is also possible to deliver the pressure switch with mixed output signals so that the output signal can be chosen at the location of use by means of jumper.
The gSPI interface is a bus system. Up to 120 pressure transmitters and pressure switches can be achieved at this. The coupling of pressure switches without gSPI interface is carried out by bus connection modules to the gSPI bus.
The pressure-metering switch are obstructed in a synthetic housing in IP65. The pressure-gauging switch can alternatively be assembled with a 4-digit LCD for the indication of the measurement. The unity is also shown on the display as well as the measurement.
The pressure-metering transmitter can instead be distributed for pressure also in a extreme-grade steel execution. The pressure can be measured in liquids and aggressive conditions with that. At this version the gauging item consists of a pressure sensor established in thin film technology on a extreme-grade steel membrane. It is therefore guaranteed that all medium touching parts consist of exorbitant-grade steel completely. A wheatstone resistance bridge circuit is used for the detection also at this pressure sensor. By use of a semiconductor chip the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Previous to delivery this pressure switch is also calibrated to be able to attest a extreme precision and accuracy.
This pressure-measuring switch can be delivered with the output signals 0 …. 10 V, 4 …. 20 mA or 0 …. 20 mA.
The use of these pressure switches is carried out in the clean room, medication and filtering technique in ventilating systems and climate channels into paint spraying cabins or into canteen kitchens.
Each pressure switch can be distributed on call with a calibrating certificate also with DKD-calibrating testification.
Do you have even further disbelieves? Use our contact form!

pressure switch with lcd in high-grade steel
You find a short statement of the technical data of the pressure-metering switch into plastic housings here:
| feature | summarization |
| output | 0 … 10 V // 4 … 20 mA // gSPI other variants: inverse output // output with root extraction |
| Pressure sensing element | Pressure detector in silicon technology with a wheatstone resistance bridge |
| power Supply | 14 … 30 V DC // 24 V AC |
| non linear error | +/- 1,0 % FS |
| total error | +/- 2,5 % FS |
| electrical connection | Solderless plug |
| method combination | tube combination 5,5 mm |
| process temperature | 0 … + 50 °C other ranges in approval to client demands |
| enviromental temperature | 0 … + 50 °C other ranges in approval to client demands |
| case | plastic material |
| safety class | IP 65 |
| liquid crystal display | upon call for with 4 digit LCD |
Which standard measurement ranges do we provide? Look!
| measurement range | maximum pressure |
| 0 … 100 / 0 … 200 / 0 … 400 Pa (0 … 1 / 0 … 2 / 0 … 4 mbar) with jumper selectable |
2 kPa (20 mbar) |
| 0 … 250 / 0 … 500 / 0 … 1000 Pa (0 … 2,5 / 0 … 5 / 0 … 10 mbar) with jumper selectable |
10 kPa (100 mbar) |
| 500 / 1000 / 2000 Pa (5 / 10 / 20 mbar) with jumper selectable |
10 kPa (100 mbar) |
| 1000 / 2000 / 4000 Pa (10 / 20 / 40 mbar) with jumper selectable |
25 kPa (250 mbar) |
| 0 … 1250 / 0 … 2500 / 0 … 5000 Pa (0 … 12,5 / 0 … 25 / 0 … 50 mbar) with jumper selectable |
25 kPa (250 mbar) |
| other alternatives: (0 … +x) kPa; (-x … +x) kPa; (-x … 0) kPa other ranges according to customer requirements |
You are interested in the version into high-grade iron steel? You find the technical data of the pressure switch here:
| feature | description |
| output | 0 … 10 V // 4 … 20 mA // gSPI other variants: inverse output // output with root extraction |
| Pressure sensing element | Pressure detector in thin film technology with a wheatstone resistance bridge circuit |
| power Supply | 14 … 30 V DC // 15 … 27 V AC |
| non linear error | +/- 0,5 % FS |
| total error | +/- 0,7 % FS |
| electrical connection | connector DIN EN175301-803 BF C others in grant to customer demands |
| method combination | G 1/4″ others in approval to customer demands |
| process temperature | - 20 … + 85 °C other ranges in approval to client demands |
| enviromental temperature | - 20 … + 85 °C other ranges in approval to client demands |
| case | metall material others in grant to customer requirements |
| safety class | IP 65 |
| membrane | extreme-grade iron steel without oil intermediate layer |
| overload range | 1,5-fold |
| max. pressure load | 2-fold |
You find a survey of the measurement ranges of the pressure switch into high-grade steel here:
| measurement range | static pressure | maximum pressure |
| 40 … 300 kPa (0,4 … 3 bar) | 600 kPa (6 bar) | 900 kPa (9 bar) |
| 60 … 500 kPa (0,6 … 5 bar) | 1 MPa (10 bar) | 1,5 MPa (15 bar) |
| 0,15 … 1,5 MPa (1,5 … 15 bar) | 2,5 MPa (25 bar) | 3 MPa (30 bar) |
| halving / doubling measurement range by jumpers changing polarity of the process connections by jumpers other ranges according to customer requirements |
||
Convinced You? Then contact us now!
Hints
You may link to this page!
The pressure switch is maintenance-free.
This page was arranged with care. It, even so, was not possible to take into account all conceivable function circumstances. If you should miss notes for your particular formulation, use the contact form for your questions.
Indications for safety causes
Notice the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) absolutely for assembly, putting into operation and operation of these pressure switches.
Mistakes and changes in the sense of technical improvements reserved.
Print This Post